Document No: 9100-127-1231-99

Issued: November, 2011

Sheet 1 of 2

INSTALLATION INSTRUCTIONS and PARTS LIST

SINGLE, DUAL and RETRO FIXTURES

MINI L-810 OBSTRUCTION LIGHT

-------------------------------------------------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------------------------------------------------

1501 Route 34 South, Farmingdale, NJ 07727 Tel: [732] 919-3119 Fax: [732] 751-5778 www.dialight.com

Model No

Description

Model No

Description

Model No

Description

RTO 1x07 xxx

120-240 VAC, FAA

RTO 6x07 xxx

120-240 VAC, Canada

RTO 0x07 xxx

120-240 VAC, NonFAA

RTO 1x06 xxx

277 VAC

RTO 1x08 xxx

12-48 VDC

RTO 2x07 xxx

120-240 VAC, C1D2

RTO BW07 xxx

120-277 VAC

RTO CR07 xxx

120-240 VAC, IR

RTO CR08 xxx

12-48 VDC, IR

RTO 1R18 xxx

12-48 VDC

RTO 6CR7 xxx

120-240 VAC, Canada IR

5th digit ... x = color last 3 digits ... 001 = Single 002 = Dual 004 = Retro

WARNING:

DE-ENERGIZE CIRCUIT BEFORE INSTALLING OR WORKING ON FIXTURE

The light assembly fixture can be mounted in any position. When mounted 'upright' [as illustrated] the fixture will meet the
designed optical specifications for Aircraft Obstruction Warnings. When mounted in any other position, the fixture will not
meet the designed optical specifications mentioned and will be considered as a visual signal fixture.

SINGLE FIXTURE INSTALLATION STEPS:

► The wire housing 2A has a 1” NPT [3/4" bushing] end to be assembled to

conduit [right angle or vertical]

Use a 1-1/2” wrench to tighten and attach the wire housing 2A to the conduit

Remove reducing bushing 5 if threading into 1” NPT conduit

Use 1” NPT plug 4 to close threaded opening not being used

► Feed the supply wires through the conduit and wire housing 2A leaving

approx 6” of wire for termination inside the wire housing 2A .

► Electrically connect the supply wires to the light assembly 1 wires

Connect the light assembly wire [with voltage label]
to the Hot AC line or Positive [+] line

Connect the light assembly wire [without label]
to the Neutral AC line or Negative [-] line

Connect the light assembly green grounding wire to the Ground line

► Tuck the connected wires inside the wire housing 2A .
► Position light assembly 1 over the wire housing 2A and secure using the holding screws 3 .
► Restore power and verify operation

DUAL FIXTURE INSTALLATION STEPS:

► The dual housing 2B has a 1” NPT end to be assembled to conduit

Remove reducing bushing 5 if threading into 1” NPT conduit

Use a 1-1/2” wrench to tighten and attach the dual housing 2B to the conduit

Tighten the 1/4 screw 3 to secure the dual wire housing in position

► Feed the supply wires through the conduit and dual housing 2B leaving

approx 6” of wire for termination inside the wire housing 2B .

► Electrically connect the supply wires to the light assembly 1 wires

same as SINGLE FIXTURE installation

► Tuck the connected wires inside the dual housing 2B .
► Position each light assembly 1 over the dual housing 2B and use

the holding screws 3 to secure the light assembly in place

► Restore power and verify operation