MoTeC DBW-4 User Manual

Page 10

Advertising
background image

MoTeC DBW-4

10

Introduction

Step 5:

This step is only applicable for DBW throttle bodies with a linear characteristic for the Meas2 (TP2) sensor (ie. Meas2
Max % Target = 100%), where the high limits for both measured values are set at the same time.

Set the high limits for the measured values by following the instructions displayed (see below). For indication
purposes, the raw position values for the two measured values will be displayed as the butterfly valve position is
changed. Note that the Set button can be pressed again if the butterfly position was set incorrectly. When the high
limit positions have been set, click Finished to continue.

Step 6:

This step is only applicable for DBW throttle bodies with a “knee” characteristic for the Meas2 (TP2) sensor (eg.
Meas2 Max % Target = 62.5%), where the high limit is measured separately for measure value 1 (TP) and measured
value 2 (TP2).

Set the high limit for the measured value 1 (TP) by following the instructions displayed (see below). For indication
purposes, the raw position values for measured value 1 will be displayed as the butterfly valve position is changed.
Note that the Set button can be pressed again if the butterfly position was set incorrectly. When the measured value
1 high limit position has been set, click Next to continue.

Step 7: