Appendix e: dbw-4 to m800 wiring, Motec dbw-4 18 introduction, Dbw-4 power and ground wiring – MoTeC DBW-4 User Manual

Page 18

Advertising
background image

MoTeC DBW-4

18

Introduction

Appendix E: DBW-4 to M800 Wiring

See pin list

Ground

DBW-4

ECU

See pin list

Power

47

CAN-LO

CAN-LO

B24 / 47

54

CAN-HI

CAN-HI

B23 / 48

CAN-LO

CAN-HI

Any Other

CAN Device

1

0

0

R

1

0

0

R

See the CAN Bus

Wiring Specification

for more Detail

CAN Cable

Connector

Any Other

CAN Device

0V

1

8V

3

CAN-LO

4

CAN-HI

5

2

0V

8V

72

71

Bat -

Bat +

DBW-4 Power and Ground Wiring

Bat +

Bat -

28, 29, 30, 37, 38, 39

13, 14, 15, 19, 20, 21, 22

Additional Power and Ground pins are provided to simplify and to meet the current requirements of any devices
connected to the PWM outputs.

As a general principle, if no outputs are being used, then wiring one power and one ground pin is sufficient. If the
DBW-4 outputs are used, then all power and ground pins should be wired up.

Wire to suit connector : 22# Tefzel, Mil Spec : M22759/16-22