Configuring basic can with an adl, Configuring basic can with an m800 – MoTeC PLM User Manual

Page 23

Advertising
background image

MoTeC

PLM Communications

23

For use with MoTeC equipment (ADL or M800), the selected table must be
setup for Lambda with 3 decimal places. Other table setups should only be
used for interfacing with third party equipment.

Configuring Basic CAN with an ADL

To connect a small number of PLM units (maximum of six) to an ADL, the ADL
must use one CAN template (PLM#1 to PLM#6) for each PLM.

The PLM units must be configured as follows to match the ADL templates.

Output To Transmit

LA V1, with 3 decimal places in the table

Address Format

Standard

Address

As per ADL template (460 to 465)

Compound Id

Message 1 = 0

Message 2 = 1

Message 3 = 2

Message 4 = 3

Message Rate

Message 1 = User defined

Message 2 = User defined

Message 3 = User defined

Message 4 = User defined

Collect Master = Off

Configuring basic CAN with an M800

Up to 12 PLM units can transmit to an M800 ECU if configured as follows:

Output To Transmit

LA V1, with 3 decimal places in the table

Address Format

Standard

Address

PLM 1 = 460

PLM 2 = 461

….

PLM 12 = 46F