3 user control, 1 to save user, 2 to call user – CEMB USA C73-L SE (B) User Manual

Page 14: 4 result of measurement

Advertising
background image

14

Use and maintenance manual Rev. 10-2009

ENGLISH

5.3 USER CONTROL

The wheel balancer can be used simultaneously by 4 diffe-
rent users who, through a simple sequence, can memorize
their work condition and call it when needed. The users’
names can be memorized (

PRESETTING THE CUSTOMER

AND USER NAME

).

5.3.1 To save USER

Pr

eset the dimensions correctly according to the proce-

dures already described in sections

AUTOMATIC

PRESETTING

.

Press

; the “MENU” window appears on the

monitor.

Press

; a window appears with the list of availa

ble USERS. The current user is displayed in red.

Press the number corresponding to the required USER.

The system returns to the initial screen automatically.

5.3.2 To call USER

Perfor

m a measuring spin with any dimensions.

Press button

; the “MENU” window appears on

the

screen.

P

ress

: a window appears with the list of avai

lable USERS. The current user is displayed in red.

Press the number corresponding to the required USER.


The system automatically returns to the initial screen

with recalculation of the unbalance values on the basis

of the effective dimensions of the USER called.

INDICATION

The dimensions memorized as USER are lost when the

machine is switched off.

The USER control is also valid for the ALUS

dimensions.

The current USER is always displayed in the

Measurements and Dimensions screens.

Use of the wheel balancer

5.4 RESULT OF MEASUREMENT

After performing a balancing spin, the unbalance values are
displayed as well as arrows useful for positioning the point
of application of the correction weight. After positioning of
the wheel, apply the weight in the 12 o’clock position. When

the beep signal is enabled (

ACUSTIC SIGNAL

), reaching

of the correction position is accompanied by a “beep”. If the
unbalance is less than the chosen threshold value, the “OK”
appears instead of the unbalance value to indicate,
on that particular side, the wheel is in tolerance; the resi-

dual unbalance can be displayed by pressing button
with an accuracy of 0.5 g (0.1 oz).

The following buttons are enabled:

Display of residual unbalance

Selection of correction mode (STATIC/DUAL

SURFACE). When the mode is changed, the

unbalance values are recalculated automatically

on the basis of the previous spin.

When this push button is held down for more

than 1.5 seconds, eccentricity measurement is

temporarily disenabled (enabled in

SPECIAL

FUNCTIONS

). To re-enable eccentricity measure

ment, press push button [4] again for more than

1.5 seconds. Every time the machine is switched

on, the status of eccentricity measurement refl ects

the settings in

SPECIAL FUNCTIONS

.

Split control for splitting of unbalance over preset
table components (

“SPLIT” CONTROL

). Button

only enabled in STATIC or ALUS correction.

Indication of the longitudinal position of the unba-
lance

(

INDICATION OF EXACT CORRECTION

WEIGHT

POSITION

) is enabled.

For selection of special functions