Diagnostics, English – CEMB USA C73-L SE (B) User Manual

Page 24

Advertising
background image

24

Use and maintenance manual Rev. 09-2009

ENGLISH

WARNING

T

HE

INFORMATION

IN

THE

POSSIBLE REMEDY

COLUMN

REQUIRES

WORK

TO

BE

PERFORMED

BY

SPECIALIST

TECHNICIANS

OR

OTHER

AUTHOR

-

ISED

PEOPLE

WHO

MUST

ALWAYS

WORK

USING

THE

P

ERSONAL

P

ROTECTIVE

E

QUIPMENT

INDICATED

IN

THE

INSTALLATION

MANUAL

. I

N

SOME

CASES

,

THIS

WORK

CAN

BE

PERFORMED

BY

A

NORMAL

OPERATOR

.

ERRORS

CAUSES

CONTROLS

Black

The wheel balancer does not switch on.

1.

Verify correct connection to the mains.

2.

Verify and eventually replace the fuses on the power card.

3.

Verify monitor function.

4.

Replace the computer board.

Err. 1

No rotation signal.

1.

Check in self-diagnostics that the encoder functions properly

.

2.

Replace the phase pick-up board.

3.

Replace the computer board.

Err. 2

Speed too low during detection.
During unbalance measurement rotation,
wheel speed is less than 42 rpm.

1.

Make sure that a vehicle wheel is mounted on the wheel balancer.

2.

Check in self-diagnostics that the encoder functions properly

3. Disconnect the piezo connectors from the board and do a spin

(if no error is detected, replace the piezo sensors).

4.

Replace the computer board.

Err. 3

Unbalance too high.

1.

Verify wheel dimension settings.

2.

Check detection unit connections.

3.

Perform machine calibration.

4.

Mount a wheel with more or less known unbalance (less than 100
grammes) and verify the response of the machine.

5.

Replace the computer board.

Err. 4

Rotation in opposite direction.
After pressing [START], the wheel
starts turning in the opposite direction
(anticlockwise).

1.

Check in self-diagnostics that the encoder functions properly

2. Check the bearing/spring of the phase generator

Err. 5

Guard open
The [START] pushbutton was pressed
without fi rst closing the guard.

1.

Reset the error by pressing pushbutton [7]=End.

2.

Close the guard.

3.

Verify the function of the protection uSwitch.

4.

Press the [START] pushbutton.

Err. 7 /
Err. 8

NOVRAM parameter read error

1.

Repeat machine calibration

2.

Shut down the machine.

3.

Wait for a minimum time of ~ 1 Min.

4.

Re-start the machine and verify correct operation.

5.

Replace the computer board.

Err. 9

NOVRAM parameter write error.

Replace the computer board.

Err. 11

Speed too high error.
During unbalance measurement rotation,
wheel speed is more than 270 rpm.

1.

Check if there is any damage or dirt on the timing disc.

2.

Check in self-diagnostics that the encoder functions properly

.

3.

Replace the computer board.

Err. 12

Unbalance measuring cycle error.

1.

Verify phase pick-up board function.

2.

Verify correct motor operation.

3.

Replace the computer board.

Err.13/
Err.14/
Err.15/
Err.16/
Err.17/
Err.18

Unbalance measurement error.

1.

Check in self-diagnostics that the encoder functions properly

2.

Check detection unit connections.

3.

Verify machine earth/ground connection.

4.

Mount a wheel with more or less known unbalance (less than 100
grammes) and verify the response of the machine.

5.

Replace the computer board.

Diagnostics

9. Diagnostics

Advertising