8.2 PRESETTING THE CUSTOMER AND

USER NAME

The machine can be customized by presetting:
a) The name appearing on the Initial screen (screen-save).
b) The name of 4 different machine users (USER NAME).
An “ideal” keyboard appears on the monitor with the set of
characters available for composition of the wordings.
The Customer’s name consists of three lines, each max. 30
characters. The USER NAME consists of a wording max. 15
characters.

8.3 CALIBRATIONS

When

is pressed from the Special Functions menu,

access is gained to the Calibration menu.

8.3.1 Gauge calibration

8.3.1.1 Distance gauge calibration

To calibrate the distance gauge, set it in rest position and
then on the adapter plane.
When done, set the gauge in rest position. If calibration is
correct, the wheel balancer is ready for operation, otherwise
an error message may be displayed if there are errors or
malfunctioning; in this case repeat calibration.

to cancel the distance gauge calibration

function if has erroneously been accessed.

8.3.1.2 Diameter gauge calibration

To calibrate the diameter gauge, place it on the adapter

fl ange and press

. For better calibration turn the gauge

downward and position it 40 mm away from the adapter plane.
On the screen a value is shown near the word POS: if it is
256+/- 3°, set the gauge to rest position, otherwise press

.

to cancel the diameter gauge calibration function if

it has erroneously been accessed.

8.3.1.3 Width gauge calibration

When calibrating the width gauge, set a measurable di-

mension as follows:

A -

GAUGE “ZERO” DISTANCE

SONAR “ZERO DISTANCE

Press [F1], [F2] to set the distance in mm between the
SONAR sensor and the distance gauge clip in pos. 0.

to

confi rm.

to cancel the width gauge calibration function if it

has erroneously been accessed.

8.3.2 Balancing machine calibration

To calibrate the balancing machine, use a wheel with steel
rim of average dimensions, e.g. 6” x 14” (±1”).

To properly perform the procedure:

Mount a wheel on the machine, even unbalanced, and

very carefully set its dimensions.

INDICATION

Setting incorrect measurements will result in the machine
not being correctly calibrated, and balancing of subse-
quent wheels will hence be incorrect until the machine is

recalibrated with the correct measurements!!

Follow the on-screen instructions.

8.4 WHEEL BALANCING MACHINE SELF

TEST

An automatic self-diagnostic cycle is provided for easier
trouble-shooting (

Consult the extraordinary mainte-

nance manual or contact Technical Service).