6.1 - SELF-DIAGNOSTICS
In Setup, selecting diagnosis gives
:
DISPLAY TEST
- All the LEDs and the displays should light up simultaneously.
- On the right-hand display the current position of the wheel is indicated
with a number from 0 to 255. Turning the wheel in the direction of
rotation, the number displayed should increase. Turning the wheel in the
opposite direction of rotation the number displayed should decrease.
With one full turn of the wheel the number zero should appear only once.
- Control parameter
- Checking parameter for technical service
- Checking parameter for technical service
- Displays values of rim DISTANCE sensor
- Displays values of DIAMETER sensor
END OF AUTODIAGNOSTICS