CEMB USA C206 (A) User Manual
Page 16

I 0638
-
16
GB
6.2 - SELF-CALIBRATION
For machine self-calibration proceed as follows:
- Fit a medium-sized wheel with steel rim on the shaft. Example: 6” x 14” (± 1”)
- Preset the exact dimensions of the wheel mounted.
CAUTION!!
Presetting of incorrect dimensions would mean that the machine is not correctly calibrated,
therefore all subsequent measurements will be incorrect until a new self-calibration is performed
with the correct dimensions!
- Perform a manual spin under normal conditions
- Add a sample weight on the outside in any angular position.
Sample weight: 60 g. (2.00 .oz) for car
300 g. (10.0 .oz) for truck
- Perform a manual spin under normal conditions
- Shift the sample weight from the outside to the inside keeping the same
angular position.
- Perform a manual spin under normal conditions
- Shift the sample weight to the 12 o’clock position.
END OF SELF-CALIBRATION
CANCELS SELF-CALIBRATION IN ANY PHASE.