6 - Set-up

6.1 - Autodiagnostics

Performs tests useful for maintenance staff.

6.2 - Autocalibration

For autocalibration proceed as follows:

- Fit a wheel with steel rim of average dimensions on the shaft. Example 6” x 14” (± 1”)

- Set the exact dimensions of the wheel mounted.

CAUTION !! Setting incorrect dimensions will result in the machine not being properly calibrated and hence all the

subsequent measurements will be incorrect until a new autocalibration is performed with the correct

dimensions!!

- Perform a manual spin

- Add a 100 g. sample weight (3.5 oz) on the outside in any angular position.

- Perform a manual spin

- Shift the sample weight from the outside to the inside keeping the same

angular position.

- Perform a manual spin

- Turn the wheel until the sample weight is in the 12 o’clock position.

END OF AUTOCALIBRATION

CANCEL AUTOCALIBRATION IN ANY PHASE