CEMB USA C75SE (C) User Manual

Page 15

Advertising
background image

I 0322 - 14

I 0322 - 15

/

/

10

GB

GB

5.3.1.3 - WHEELS ALU-S

After the measurement performed for the FI inner side, as indicated in fig. 8/9, pull out the gauge again to

store the data for the FE outer side; choose position A or B (fig. 8) at your choice. Keep this position for at

least 2 seconds. The counterweight symbols change colour.

When the acoustic signal is enabled (see

ACOUSTIC SIGNAL

), the acquisition is accompanied by a “beep”.

After having detected the dimensions, use the

key to indicate the type of correction selected for the

inner side.

The following buttons are enabled:

Management of save user recall

Selection of clip or adhesive weight for inside.

Only for automatic width option:

The

L.T. key (LIGHT TRUCK) used to improve the dimensional calibration of large-diameter wheels

such as off-road, trucks, wheels which protrude significantly from the rim. Press the

L.T. key, after

distance measurement, immediately before lowering the guard for Width Measurement.

The option is disengaged at the end of current Width Measurement.


Selecting the manual dimension presetting screen

Return to initial screen

Balancing run

Position of

adhesive

weights

Advertising