7.4.2 - WHEEL BALANCER CALIBRATION

For calibration of the machine, proceed as follows:

- Use a medium-sized metal wheel. Example: 6" x 14" (± 1")

- Preset the wheel dimensions with

GREAT CARE.

- Follow the instructions appearing on the monitor.

7.4.3 - AMBIENT TEMPERATURE

Ambient temperature is important for correct use of the sonars. Set the average temperature of the area

where the wheel balancer is installed.

7.4.4 - SELF-DIAGNOSTICS

An automatic self-diagnostics cycle is provided for easier trouble shooting. At the end of the self-diagno-

stics cycle, several parameters are displayed which are useful for the Technical Service Department in

order to identify machine faults.

: returns to previous menu.

7.4.4.1 - TO CHECK THE ENCODER

When the spindle is rotated:

- the angular position “POS” should vary from 0 to 128;

- the wording

“UP” should appear when rotated clockwise and “DOWN” when rotated in the opposite

direction.

tyre

Encoder check

Check for correct opera-

tion of the distance gauge;

the number increases

when the gauge is pulled

out.

Check for correct ope-

ration of the diameter

gauge; the number

increases when

the gauge is rotated

outwards

Check of the width

sonar: the number

decreases when a

surface is approached

to the sonar

Check of the eccentricity sonar (option):

the number decreases when a surface

is approached to the sonar

In the event of failure or faulty operation of the wheel balancing machine, notify the Technical Service of all

the parameters displayed.