CEMB USA C72 (B) User Manual

Page 13

Advertising
background image

I 0307_0308 -

13

GB

The LT script on the LH matrix display indicates that LIGHT TRUCK wheel measurement is set (large
dimension wheels such as off-road, trucks or wheels which protrude signifi cantly from the rim).

This function can be enabled/disenabled by pressing push button

prior to the measurement, which

is then performed by closing the guard; once completely closed and if “automatic START on guard closure”
is enabled, the launch will be made for unbalance measurement. If automatic START is disenabled, once
the guard is closed the display will show the width value measured.

5.2.1.2 - WHEEL ALU-S
(correction from inside for two balancing planes with direct calibration):

After measurement for inside F1 as shown, again remove the gauge in order to memorize the data for the
outside FE; keep the position for at least 2 seconds. The measurement can be made either in the position
shown in Fig. 8/Pos.A or in Fig. 8/Pos.B.
Manual presetting is possible by using the push buttons as for detailed hereunder.

Fig. 9

5.2.1.1 - “AUTOMATIC WIDTH” OPTION
If WIDTH measurement with sonar is enabled, the machine is set for the acquisition of this value:

Fig. 10

Advertising