6.2 - SELF-CALIBRATION

For machine self-calibration proceed as follows:
- Fit a medium-sized metal wheel on the shaft. Example: 6” x 14” (± 1”)
- Preset the exact dimensions of the wheel mounted.
CAUTION!!

Presetting of incorrect dimensions would mean that the machine is not correctly

calibrated, therefore all subsequent measurements will be incorrect until a new self-

calibration is performed with the correct dimensions!

- Perform a spin under normal conditions.

- Add 100 g (3.5 oz) on the outside in any angular position.

- Shift the 100 g. weight from the outside to the inside keeping
the same angular position.

- Shift the 100 g. weight to the 12 o’clock position.

END OF SELF-CALIBRATION

CANCELS SELF-CALIBRATION IN ANY PHASE