If you need to use your own Software Control program from a PC

or automation, the device allows communication through an ASCII

code protocol. All commands can be found on

www.analogway.com

,

in the [Technical Support] menu, [User’s Manuals] menu.

All Analog Way products equipped with an RS232 input are

compatible with Crestron, AMX, Medialon, and most major control

systems. TCP/IP control ports are also available on most Analog

Way products, as standard or as options.

To control an

PLS200 product with an External Remote Controller

(PC Software Control - Touch Pad Controller…) follow the indications

below:

1/ First establish an

RS232 communication between the Remote

Control Software and the

PLS200, in order to setup the LAN

parameters of the product.

2/ In the “Control” - “

Pulse LE LAN Setup” menu, configure the

connection of the PLS-200 product in UDP mode and setup the

Local and Remote Addresses as well as the Local and Remote

Ports in concordance with your Network.

3/ Configure the TCP/IP address of your External Remote Controller.

In example: 192.168.000.001

4/ Setup the UDP connection of your External Remote Controller in

concordance with your Network.

In example on the Remote Software in the “Control” - “RS232/LAN

Setup” - “LAN/Setup” menu :

5/ Setup the LAN parameters in UDP mode in the “Console” - “LAN

Setup” menu.

In example:

RK Address:

192.168.000.002

Remote

Address:

192.168.000.010

Gateway

Address: 192.168.000.001

RK

Port:

10500

Remote

Port:

10500

Netmask:

255.255.255.000

6/ Select the LAN communication port in the remote controller

console - “RS232/LAN port” menu.

7/ You can now control your

PLS200 product with an External

Remote Controller.

7-3. EXTERNAL PROGRAMMING