8-6. COMMUNICATION PORTS

8-7. TRIGGER

8-8. ENVIRONMENTAL

RS232 (on DB9 female connector)

Data Rate :

9600 Bauds, 8 data bits, 1 stop bit, no parity bit, no flow control.

Pin-out :

PIN #

FUNCTIONS

2

Tx1 (transmit data to the control device)

3

Rx1 (receive data from the control device)

4

Rx2 (receive data from the display device)

5

GROUND (Gnd)

8

Reserved for manufacturer.

9

Tx2 (transmit data to the display device)

LAN

Protocol :

TCP (Transmission Control Protocol) / UDP (User Datagram Protocol).

Data Rate :

10 / 100 Mbps.

LED functions (on RJ45 connector) :

Left LED

Right LED

Meaning

OFF

OFF

No link

OFF

ON

100 BASE-T link.

ON

OFF

10 BASE-T link.

Connector :

Jack 3.5 mm female.

Command levels :

ON

= + 12 Vdc trigger.

OFF

= 0 Vdc.

Output Current :

0.1 A max at + 12 Vdc.

NOTE : This output is activate with the AC Power Switch (ON/OFF).

Power Supply :

Internal CE / UL / CSA / IEC 950 (50 W), universal, automatic.

Input : 100 VAC to 250 VAC; 50-60 Hz; I = 1 A Max.

Storage Temperature :

- 40 °C to + 70 °C (- 40 °F to + 158 °F).

Operating temperature :

0 °C to + 50 °C (32 °F to 122 °F).

Hygrometry :

10% to 80% (without condensation).

Dimensions :

D 265 x W 482 x H 44 mm / D 10.4” x W 19” x H 1.74”.

Compatible with the 19” rack (height = 1 unit).

Weight :

3.5 kg / 7.7 lbs.