Stopping domestic hot water production, Other settings – DE DIETRICH VIVADENS MCR 24, MCR .._.. MI User Manual
Page 17
4.3.5.
Stopping domestic hot water production
1. Press the N key.
The symbol N and the current temperature are displayed.
2. Press the key [-] several times until the value 0ff is displayed.
3. To confirm the new value, press the key S.
The symbol T appears.
It also possible to modify this setting using the parameter
p3
. ¼See chapter: "Other settings", page 16.
4.3.6.
Other settings
Parameter Description
Adjustment range
Factory setting
MCR 24
MCR 24/28
MI
MCR 30/35
MI
MCR 34/39
MI
p1
Flow temperature
20 to 85 °C
75 °C
75 °C
75 °C
75 °C
p2
Domestic hot water
temperature
40 to 65 °C
55 °C
55 °C
55 °C
55 °C
p3
Heating / DHW mode
0 = Heating deactivated (C) / DHW
deactivated (T)
2
1
1
1
1 = Heating activated (D) / DHW
activated (N)
2 = Heating activated (D) / DHW
deactivated (T)
3 = Heating deactivated (C) / DHW
activated (N)
("
"KK
T000142-A
MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI
4. Operating the appliance
160513 - 300015874-001-01