Stopping domestic hot water production, Other settings – DE DIETRICH VIVADENS MCR 24, MCR .._.. MI User Manual

Page 17

Advertising
background image

4.3.5.

Stopping domestic hot water production

1. Press the N key.

The symbol N and the current temperature are displayed.

2. Press the key [-] several times until the value 0ff is displayed.
3. To confirm the new value, press the key S.

The symbol T appears.

It also possible to modify this setting using the parameter
p3

. ¼See chapter: "Other settings", page 16.

4.3.6.

Other settings

Parameter Description

Adjustment range

Factory setting

MCR 24

MCR 24/28
MI

MCR 30/35
MI

MCR 34/39
MI

p1

Flow temperature

20 to 85 °C

75 °C

75 °C

75 °C

75 °C

p2

Domestic hot water

temperature

40 to 65 °C

55 °C

55 °C

55 °C

55 °C

p3

Heating / DHW mode

0 = Heating deactivated (C) / DHW

deactivated (T)

2

1

1

1

1 = Heating activated (D) / DHW

activated (N)
2 = Heating activated (D) / DHW

deactivated (T)
3 = Heating deactivated (C) / DHW

activated (N)

("



"KK

T000142-A

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

4. Operating the appliance

160513 - 300015874-001-01

16