Technical specifications, 7 technical specifications, 1 technical specifications – DE DIETRICH VIVADENS MCR 24, MCR .._.. MI User Manual

Page 29

Advertising
background image

7 Technical specifications

7.1

Technical specifications

Boiler type

MCR 24

MCR 24/28
MI

MCR 30/35
MI

MCR 34/39
MI

Heating mode

Nominal useful output 40/30

(min / max)

kW

6.3 /25

6.3 /25

6.6 /31.3

6.8 /35.5

Nominal useful output 80/60

(min / max)

kW

5.5 / 23.6 5.5 / 23.6

5.7 / 29.5

5.9 / 33.3

Nominal input power

kW

24

24/28

30/35

34/39

Minimum input power

kW

5.8

5.8

6.1

6.3

Domestic hot water mode Nominal useful output

kW

-

27.4

34.3

38.2

Nominal input power

kW

24

24/28

30/35

34/39

Minimum input power

kW

5.8

5.8

6.1

6.3

Gas flow rate at nominal

output (15 °C -

1013 mbar)

Natural gas H (G20)

m

3

/h

2.4

2.4

3.5

3.9

Natural gas L (G25)

m

3

/h

2.8

2.8

4.1

4.5

Propane (G31)

Kg/h

1.9

1.9

2.7

3.0

LHV efficiency

100% of nominal output and

average water temperature in

the boiler of 70°C

%

98.3

98.3

98.2

98

100% of nominal output and

return temperature of 30°C

%

104.4

104.4

104.4

104.4

30% of nominal output and

return temperature of 30°C

%

108.7

108.7

109.7

110.5

HHV efficiency

100% of nominal output and

average water temperature in

the boiler of 70°C

%

88.5

88.5

88.4

88.2

100% of nominal output and

return temperature of 30°C

%

94

94

94

94

30% of nominal output and

return temperature of 30°C

%

97.9

97.9

98.8

99.5

Maximum temperature (Safety thermostat cut-off)

°C

110

110

110

110

Stand-by losses (ΔT = 30 °C)

W

30

30

29

28

Losses through the outer casing

%

1.1

1.1

0.9

0.5

Water content

litres

1.7

1.8

2

2.2

Weight empty, without mounting frame, without front cover kg

29

30.5

32

31.5

Heating circuit
Nominal water flow (ΔT = 20 K)

m

3

/h

1.03

1.03

1.29

1.47

Manometric height (ΔT = 20 K)

mbar

(1)

> 250

> 250

> 200

> 200

Flow temperature

°C

75/85

75/85

75

75

Maximum pressure

bar

3

3

3

3

Expansion vessel

litres

8

8

8

-

Initial pressure of the expansion vessel

bar

1

1

1

1

Minimum operating pressure

bar

0.8

0.8

0.8

0.8

Domestic hot water circuit
Instruction set outlet temperature

°C

55

55

55

55

(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG

(2) Cold water inlet temperature: 10 °C

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

7. Technical specifications

160513 - 300015874-001-01

28

Advertising