DE DIETRICH VIVADENS MCR 24, MCR .._.. MI User Manual
Page 30
Boiler type
MCR 24
MCR 24/28
MI
MCR 30/35
MI
MCR 34/39
MI
Specific hot water flow (ΔT = 30 K)
(2)
litres per
min.
-
14
16
19
Nominal max cold water pressure
(2)
bar
8
8
8
8
Minimum pressure for 11 l/min
(2)
bar
-
1.4
0.4
0.4
Water capacity
litres
-
40
40
40
Combustion products circuit
Connection diameter
mm
80/125
80/125
80/125
80/125
Mass flue gas flow rate (min / max)
Kg/h
10/37
10/47
10/59
10/62
Flue gas temperature 80/60
°C
78
78
74
71.5
Pressure available at the flue gas nozzle
Pa
(1)
50
100
100
140
Condensation water pH 50/30
1 - 7
1 - 7
1 - 7
1 - 7
Electricity characteristics
Power supply voltage (50 Hz)
V
230
230
230
230
Power consumption
W
115
115
150
180
Electrical power circulating pump
W
90
90
125
135
Auxiliary electrical power (nominal output, ex heating
pump)
W
25
25
25
25
Electrical protection index
IPX4D
IPX4D
IPX4D
IPX4D
(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG
(2) Cold water inlet temperature: 10 °C
7. Technical specifications
MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI
29
160513 - 300015874-001-01