4.3

Changing the settings

4.3.1.

Setting the set point temperatures

To set the various heating, DHW and swimming pool temperatures,

proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.

To go back to the previous display, press the key j.

4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.

To cancel, press key h.

Menu C

Parameter

Adjustment range Description

Factory setting

DAY TEMP. A

5 to 30 °C

Desired room temperature in comfort periods on circuit A

20 °C

NIGHT TEMP. A

5 to 30 °C

Desired room temperature in reduced periods on circuit A

16 °C

DAY TEMP. B

(1)

5 to 30 °C

Desired room temperature in comfort periods on circuit B

20 °C

NIGHT TEMP. B

(1)

5 to 30 °C

Desired room temperature in reduced periods on circuit B

16 °C

DAY TEMP. C

(1)

5 to 30 °C

Desired room temperature in comfort periods on circuit C

20 °C

NIGHT TEMP. C

(1)

5 to 30 °C

Desired room temperature in reduced periods on circuit C

16 °C

WATER TEMP.

(1)

10 to 80 °C

Desired domestic hot water temperature in the DHW circuit

55 °C

TEMP.TANK AUX

(1)

10 to 80 °C

Desired domestic hot water temperature in the auxiliary circuit 55 °C

DHW A TEMP.

(1)

10 to 80 °C

Desired domestic hot water temperature in circuit A

55 °C

SWIMMING P.T.B

(1)

5 to 39 °C

Desired temperature for swimming pool B

20 °C

SWIMMING P.T.C

(1)

5 to 39 °C

Desired temperature for swimming pool C

20 °C

(1) The parameter is only displayed for the options, circuits or sensors actually connected.

MODE

C002266-A

MCA 35

4. Operating the boiler

24/08/2011 - 300024162-001-B