In order for the regulator to calculate the quantity of heat produced by
the installation (parameter kWh), input parameter Fx. The parameter
Fx is equal to the flow in litres per minute in the solar circuit.
Determine the value Fx using the following tables, according to the
configuration of the installation and the number or surface area of the
collectors. When the flow is input incorrectly, the display kWh will also
be incorrect.



The quantity of heat (kWh value) can only be used for checks
carried out for personal reasons.

`

Flat solar panels

`

Tubular solar panels

„

Adjustment parameter MM - Operating mode

Adjustment range: 0 ... 4
Factory setting: 4
For inspection and maintenance work, it is possible to operate the
regulator in manual mode. To operate the regulator in manual mode,
it is necessary to input parameter MM from the following table.

Solar panel

installation

Area

m

2

Number of

panels

Flow rate

l/h

Flow rate

l/min

3 ... 5

1 or 2

400

6.7

6 ... 8

3 or 4

300

5

8 ... 10

4 or 5

250

4.1

8 ... 10

2x2

750

12.5

12 ... 15

2x3

670

11.2

16 ... 20

2x4

450

7.5

12 ... 15

3x2

850

14.2

18 ... 23

3x3

800

13.4

24 ... 30

3x4

650

10.9

16 ... 20

4x2

1200

20

24 ... 30

4x3

850

14.2

Number of panels

Flow rate

l/h

Flow rate

l/min

minimum: 1x4

820

13.7

1x5

750

12.5

1x6

680

11.4

1x7

610

10.2

1x8

540

9

1x9

470

7.8

1x10

250

4.1

2x3

1400

20

2x4

1250

20

2x5

1100

18.4

2x6

950

15.9

2x7

750

12.5

2x8

600

10

2x9

540

9

2x10

400

6.7

MM1

R1

R2

LED

0

Open

Open

Flashing green/red

1

Closed

Open

Flashing green/red

2

Open

Closed

Flashing green/red

3

Closed

Closed

Flashing green/red

4

automatic

automatic

automatic