3.1 Technical specifications

DIETRISOL
TRIO DT 250

DIETRISOL

TRIO DT 350

Maximum operating temperature

Solar exchangers

°C

120

120

Boiler heat exchanger

°C

90

90

tank

°C

90

90

Maximum operating pressure

bar

7

10

Maximum operating pressure in accordance with W/TPW

(1)

bar

6

6

Water content

Solar exchangers

litres

9

8.1

Boiler heat exchanger

litres

4.3

4.9

tank

litres

250

350

Surface area

Upper solar heat exchanger

m

2

0.48

0.48

Lower solar heat exchanger

m

2

0.86

0.96

Boiler heat exchanger

m

2

0.64

0.72

Operation with boiler back-up

Top up volume

litres

105

127

Solar volume

litres

145

223

Power exchanged (2) (3)

kW

21

23

Operation with electrical back-up

Top up volume

litres

130

160

Solar volume

litres

120

190

Output of the electrical back-up

kW

2.4

3

Back-up volume heating time (from 15
to 60°C)

h

2h50

2h50

Vecs 40 (5) (6)
Domestic hot water storage
temperature: 55 °C

litres

355

420

Vecs40 (5) (6)
Domestic hot water storage
temperature: 60 °C

litres

385

450

Continuous output

T = 35 K

(2) (3)

l/h

515

565

Flow rate for 10 minutes where

T = 30 K

(on make-up volume) (2)

(4)

l/10 mm

190

230

Maintenance consumption

kWh/24h

-

2.7

Cooling constant Cr

Wh/lKj

0.22

0.19

(1)

Swiss Directives

(2)

Domestic cold water input at 10°C - Primary inlet temperature at 80 °C
Values measured with a wall-mounted boiler

(3)

Domestic hot water temperature: 45 °C

(4)

Domestic hot water temperature: 40 °C

(5)

Domestic cold water inlet 15 °C

(6)

Values measured only on the back-up volume
Domestic hot water load setting: 60 °C