2 main parts, Tank, Protection against corrosion – DE DIETRICH DIETRISOL TRIO DT 250 - TRIO DT 350 User Manual

Page 8: Heat exchanger, Insulation, Casing, Solar station, Diemasol b regulator

Advertising
background image

8

TRIO DT 250 - TRIO DT 350

17/10/12 - 300028005-001-03

3.2 Main parts

Dietrisol TRIO DT ... is a high performance solar DHW tank/calorifier
designed to be connected to Dietrisol NEO or POWER solar
collectors and an De Dietrich central heating boiler.
It is designed in such a way as to be able to cope with a solar collector
surface area of up to 4.5 m

2

(DT 250) and 6.5 m

2

(DT 350) under the

conditions set out in the chapter "Hydraulic Connection Primary Solar
Circuit".

„

tank

The high quality steel tank is lined with food standard quality
vitrified enamel, which protects it from corrosion and preserves
all the qualities of the domestic water.
The Dietrisol TRIO DT ... tank is fitted with 2 heat exchangers
per zone for solar heating and one heat exchanger for
supplementary heating by means of a fuel oil or gas boiler.

„

Protection against corrosion

The tank is also protected from corrosion by two magnesium
anodes which must be inspected every 2 years and replaced if
necessary.

„

Heat exchanger

The thermal exchanger welded into the tank is made of smooth
piping, the inside of which, which is in contact with the domestic
water, is enamelled.

„

Insulation

The tank is strongly insulated with high strength rigid
polyurethane foam with no chlorofluorocarbons (CFC), 50 mm
thick to minimise heat loss.

„

Casing

The outside casing is made of painted steel sheeting.
The top and side covers are made of ABS.

„

Solar station

The solar heating pump unit comprises the solar circuit safety
unit, a pressure and temperature gauge and a flowmeter to
visualise circulation of the solar fluid between the panels and the
DHW tank. An expansion vessel is connected to the solar unit; it
is used to compensate for the expansion of the solar fluid in
which the temperature varies between 0 and 150°C.

„

Diemasol B regulator

The control system is the solar system's brain; it makes the solar
heating pump run at variable speeds according to the difference
in temperature between the bottom of the DHW tank and the
solar panels. The control system manages the set point
temperature (temperature to be attained in the DHW tank),
overheating and nighttime cooling. The control system also
displays the various operating modes, the temperatures in the
collectors and in the bottom of the DHW tank, as well as
signalling any malfunctions.

1

Pressure gauge - Primary solar circuit

2

Safety control unit for the solar circuit (6 bar)

3

Blue thermometer (tank solar heat exchangers outlet)

4

Red thermometer (tank solar heat exchangers inlet)

5

Primary solar circuit pump

6

Manual bleed degasser

7

2-position 3-way directional valve

8

Diemasol B regulator

9

8 l/6 bar expansion vessel, 2-bar pre-load

10

Automatic connection for expansion vessel

11

Primary solar circuit filling and draining device

12

Magnesium anode

13

Electric heating resistance

14

Magnesium anode

1
3

5

7

2

4
6

8

9

10

13

12

14

11

M001003