Operating the appliance, Starting and stopping the boiler, Start the boiler – DE DIETRICH VIVADENS MCR-P 24_28 BIC User Manual
Page 12: Stopping the boiler, 4 operating the appliance, 1 starting and stopping the boiler
Advertising
![background image](/manuals/329062/12/background.png)
4 Operating the appliance
4.1
Starting and stopping the boiler
4.1.1.
Start the boiler
1. Check the water pressure in the installation.
2. Open the gas valve.
3. Throw the boiler’s ON / OFF switch.
4. The start-up cycle begins. It lasts 2 minutes and cannot be
interrupted.
During the start-up cycle, the display shows the following
information:
fK[xx: Software version
pK[xx: Parameter version
The version numbers are displayed alternately.
5. When the start-up cycle is finished, the display shows 0. The
boiler is now operational.
4.1.2.
Stopping the boiler
1. Throw the boiler’s ON / OFF switch.
2. Switch off the boiler electrical power supply.
3. Close the gas valve.
A000785-A
A000787-A
A000786-A
4. Operating the appliance
MCR-P 24/28 BIC
11
060513 - 127686-01
Advertising