6.1.4.

Before contacting the installer

Before contacting the installer

Note the following information on the appliance’s rating plate:

4

Type of gas used

4

Boiler type

4

Manufacturing date

4

Serial no. of the appliance

6.2

Incidents and solutions

Problem

Probable causes

Solution

There is no domestic hot water.

The boiler is not switched on.

4

Check that the boiler is switched on.

4

Check the fuses and switches.

4

Check that the gas valve is fully opened.

The DHW mode is deactivated.

Activate the DHW mode.

¼See chapter: "Stopping domestic hot water

production", page 15.

The water pressure is too low (<

1 bar).

Top up the installation with water.

¼See chapter:

"Filling the system", page 19.

The energy-saving shower head

is restricting the water flow.

Clean the shower head; replace if necessary.

The radiators are cold.

The heating temperature setting

is too low.

Increase the value of parameter p1 or, if a room

thermostat is connected, increase the temperature.

¼See chapter: "Changing the heating

temperature", page 12.

The heating mode is deactivated.

Activate the heating mode.

¼See chapter: "Stopping the central heating or

activating the Summer mode", page 13.

The radiator valves are closed.

Open the valves on all radiators connected to the heating

system.

The boiler is not switched on.

4

Check that the boiler is switched on.

4

Check the fuses and switches.

4

Check that the gas valve is fully opened.

The water pressure is too low (<

1 bar).

Top up the installation with water.

¼See chapter:

"Filling the system", page 19.