DE DIETRICH VIVADENS MCR-P 24_28 BIC User Manual

Page 28

Advertising
background image

MCR-P BIC
Water capacity

litres

40

Combustion products circuit
Connection diameter

mm

60/100

Mass flue gas flow rate (min / max)

Kg/h

10/47

Flue gas temperature 80/60

°C

78

Pressure available at the flue gas nozzle

Pa

(1)

100

Condensation water pH 50/30

1 - 7

Electricity characteristics
Power supply voltage (50 Hz)

V

230

Power consumption

W

78 - 183

Electrical power circulating pump

W

90

Auxiliary electrical power (nominal output, ex heating pump)

W

25

Electrical protection index

IPX4D

(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG

(2) Cold water inlet temperature: 10 °C

7. Technical specifications

MCR-P 24/28 BIC

27

060513 - 127686-01