Ts series - pulse pick-ups, Hall effect sensor – Fill-Rite TS SS Electronic Precision Meter User Manual
Page 6

TS Series - Pulse Pick-Ups
1 . 6
Hall Effect Sensor
(standard pulser)
FLAME PROOF RATED SENSORS EEx d FOR ZONE 1 APPLICATIONS.
ExII 2 G CE0344 EEx d IIA T4 ITS05ATEX15076X
Initial installation occurs at the factory, where the sensor is installed in a flow meter. The user’s manual shows the sensor in
place in the flow meter. The manual includes a ‘Meter Disassembly and Repair’ section. See part A: Pulser O-ring or Pulser.
There are no replaceable parts in the sensor assembly itself. The flow meter must be drained of fluid and depressurized
before sensor replacement. The replacement sensor must be installed exactly as the original. Opening of any associated
devices to disconnect and reconnect the sensor cable must be done according to safety standards applicable to the hazard-
ous area. The cable attached to the sensor needs to be suitably protected and terminated in an ATEX approved terminal
assembly, that provides the same level of protection as the sensor itself.
INTRINSICALLY SAFE RATED SENSORS FOR Cl. I, Div. 1, Grp D and Zone 0 APPLICATIONS.
CD1002, UL 9HA6, DEMKO 04 ATEX0334817 EEx ia IIA T4 HALL EFFECT SENSORS
The standard meter pulser is a Hall Effect device, which may have one or two output signals. Some reed switch pulsers are
available for battery powered registers. A PIA-300 pulse isolator/amplifier may be required for longer cable lengths.
Features:
Color Code:
Pull-up Resistor (R1)
Supply voltage (VDC) . . . . . . : 4 to 28
Supply current (mA max.) . . . : 13.5
Output type . . . . . . . . . . . . . . : sink
Output voltage (V) @ 20 ma : 0.40max
Output current (mA max.) . . . : 20
Leakage current (µA max.) . . : 10
Magnetics type . . . . . . . . . . . : Bipolar
4
conductor
blue
cable
with
24
AWG
leads,
18”
(45
cm)
standard
RED DC
power
BLACK DC
common
GREEN Channel
B
WHITE Channel
A
BARE
SHIELD
SENSOR
RETAINING
Assembly RING
COUPLING
CABLE
GLAND
HALL
sensor
HALL
sensor
Signal A
5 to 24 VDC
Signal Common
Signal B
SHIELD
Note 1 Note 2
Notes: 1 = Cable attachment
2 = Provision for pull-up resistor
Digital current sinking output. For sourcing output, add PIA-300 signal conditioner.
Bipolar operated with alternating north and south magnetic poles.
Operating
speed : 0-100
kHz
Operating temperature : -40°F to +300°F = -40°C to +150°C
Red = Positive 4-28VDC
Black = Negative (signal common)
White = Signal output A
Green = Signal output B (optional)
The pull-up resistor provides the necessary voltage and current levels to guarantee a logic-1 level,
whenever the output transistor is in the ‘off’ state. Most sensors have internal 10K ohm pull-up resis-
tors. Some pulse receivers have pull-up resistors. Refer to the receiver’s manual.
Pull-up resistor size (kΩ) =
V
supply
(4-28 VDC)
Desired Sink Current (0-20 ma)
CAUTION
If connected incorrectly,
The pulser will be
damaged beyond repair.