Fill-Rite 111 COUNTER ASSEMBLY User Manual

Owner's operation & safety manual, Warning, Troubleshooting

Advertising
background image

Owner's Operation & Safety Manual

Owner's Operation & Safety Manual

Owner's Operation & Safety Manual

Owner's Operation & Safety Manual

Owner's Operation & Safety Manual

SERIES 100 ROTARY HAND PUMP

AND MODEL 111 COUNTER

ASSEMBLY

Models FR110, FR112, FR113

SAFETY INSTRUCTIONS

To ensure safe and efficient operation, it is essential to read and
follow each of these warnings and precautions.
1. Improper use or installation of this product can cause serious

bodily injury or death.

2. Do NOT smoke near pump or use pump near an open flame when

pumping flammable fluids. Fire could result.

3. A Fill-Rite filter should be used on pump outlet to ensure that no

foreign material is transferred to fuel tank.

4. Use gasoline and oil resistant thread sealant or sealant tape on all

threaded joints to protect against leakage.

5. Storage tank or barrel should be anchored to prevent tipping in

both the full and empty conditions.

6. To minimize static electricity build-up, keep nozzle in contact with

container being filled.

WARNING

This product should not be used for fluid transfer into aircraft. This
product is not suited for use with fluids for human consumption or
fluids containing water.
Fluid Compatibility
If in doubt about compatibility of a specific fluid, contact supplier of fluid
to check for any adverse reactions to the wetted materials.
The 100 is compatible with the following fluids:

Gasoline, Diesel, Heptane, Kerosene, Stoddard Solvent, Light Oils,
Mineral Spirits

Do NOT use the 100 with the following fluids:

Water, Sulfuric Acid, Naptha, Methanol, Methyl Ethyl Ketone (MEK),
Acetone, Ammonia, Benzene, Bleach, Chlorine

TROUBLESHOOTING

IF PUMP FAILS TO PRIME: Check suction line for leaks or obstructions.
Check vanes and slots for nicks, burrs or wear. Check rotor for
excessive wear or damage.
LOW PUMPING CAPACITY: Remove and clean screen. Check for leaks
in suction line. Check rotor and vanes for excessive wear and damage.
Check for dirty filter on outlet side.
PUMP FLUID LEAKAGE: Clean O-ring seal and seat area. Replace seal.
Replace vacuum breaker. Tighten covers and joints. Check for dirty filter
on outlet side.

INSTALLATION

NOTE: All pipe threads must have a sealant to protect against leaks.
Use sealant tape provided with the pump, or use a gasoline and oil
resistant pipe sealant.
1. Screw suction pipe into pump inlet flange and tighten.
2. Extend suction pipe into tank or barrel opening to within 3" of

bottom of tank or barrel. Do not rest suction pipe on bottom.

3. Screw inlet flange of pump completely and securely into

undamaged tank or barrel bung.

PUMPS WITH HOSE AND NOZZLE
4. Screw one end of hose into pump discharge opening and the

nozzle to other end of hose.

PUMPS WITH DISCHARGE SPOUTS
4. Screw discharge spout assembly into top of pump.

PUMPS WITH METER, HOSE AND NOZZLE
4. Screw street elbow into top of pump, nipple into street elbow,

meter onto nipple. Note: Position the meter to the right of the
handle facing operator for ease of operator viewing. Screw one
end of hose into meter outlet and the nozzle to the other end of
hose.

PUMP FLOW REVERSAL INSTRUCTIONS

1. Remove the Vacuum Breaker (item 2) and install a pipe plug.
2. Take out Check Valve Assembly (item 25).
3. Turn the handle backwards for reverse flow, normal direction

for normal flow.

1

100F0890 Counter Back

1

2

100F0900 Dial Wheel

1

3

100F1040 #10L Washer

1

4

100F1050 3/16 Prong-Lock Retainer

1

5

100F1060 Screw PHMS #8 x 3/8 (Type B)

6

6

100F0880 Counter Cover

1

7

100F0910 Dial - 20 Gallon

1

100F0915 Dial - Liter

Opt.

8

100F1010 Reset Stop Pin

1

9

100F1020 Reset Stop Spring

1

10 704F3811 1/4 Washer

2

11 100F0921 Reset Knob

1

12 100F0960 Totalizer Assembly - U.S. Gallon

1

100F0961 Totalizer Assembly - Liter

Opt.

13 100F0950 Cluster Gear Shaft

2

14 800F3830 #2S Washer

9

15 100F0940 Cluster Gear (12T/33T) - U.S. Gallon

4

16 100F0970 Drive Gear - Totalizer

1

17 100F0990 Worm (5T) - U.S. Gallon

1

100F1001 Worm (2T) - Liter

Opt.

18 100F0980 Totalizer Shaft

1

19 100F0930 Drive Gear (41T)

1

100F0935 Drive Gear (40T) - Liter

Opt.

20 100F1070 1/4-20 x 1 HHMS

2

21 100F0945 Cluster Gear (12T/34T) - Liter

Opt.

22 1200F6565 Washer, Brass

1

ITM.

ITM.

ITM.

ITM.

ITM. PART

PART

PART

PART

PART

NO NO.

NO NO.

NO NO.

NO NO.

NO NO.

D E S C R I P T I O N

D E S C R I P T I O N

D E S C R I P T I O N

D E S C R I P T I O N

D E S C R I P T I O N

QTY.

QTY.

QTY.

QTY.

QTY.

COUNTER PUMP PARTS LIST

COUNTER INSTALLATION
1. Remove crank from shaft.
2. Remove two screws directly above horizontal centerline of

pump.

3. Push drive gear onto shaft with flat in gear hole located on

longer flat of shaft.

4. Position counter on pump and attach with two screws and two

washers.

5. Reattach crank.

SAFETY APPROVAL

Advertising
This manual is related to the following products: