English, Valve construction, Circuit functions of valves type 0450 – Burkert Type 0450 User Manual

Page 10: Media

Advertising
background image

8 - 8640-0450

T

ECHNICAL

D

ATA

english

5/2 or 5/3-way valve with 3/2-way pilot valve Type 6106 (standard and impulse versions)

5/2-impulse or 5/3-way valves have double width and occupy 2 valve spaces

Valve housing aluminium, black anodized, piston slide valve, service connections

Service connections 2 (B) / 4 (A), supply and vent connection 1 (P) / 3 (R) / 5 (S) with interior thread G 1/8 G 1/8

The valve can be assembled to a valve block on Aluminium Baseplate Type MP05

Any orientation, but preferably with magnet system above

Manual override knob for manual operating of the valve

Valve construction

H 5/2-way valve:
pilot control, de-energized, output port 2 exhausted,

various reset modes including impulse valve

L 5/3-way valve:

pilot control, in middle position all connections blocked

N 5/3-way valve:
pilot control, in middle position outputs ports 2 and 4

exhausted

Circuit functions of valves Type 0450

Compressed air, lubricated, unlubricated

Sealing material

POM/NBR

Permissible temperature range

Medium

- 10 to + 70 °C

Ambient

- 10 to + 55 °C

Operating pressure range

2 - 8 bar or 2 - 10 bar

ATTENTION!

Observe the permissible pressure range on the nameplate!

Pressure difference between connections 1 and 3

≥≥≥≥≥

2 bar

At temperatures below 0 °C, operation is limited to dried air.

Media

Example
permissible pressure

NOTE

By sealing a service connection, the 5/2-way valve may be simply converted into a 3/2-way valve:

Service connection 2

=>

Circuit function C

Service connection 4

=>

Circuit function D