The valves work without maintenance, even when running dry.

Trouble shooting

Maintenance

Fault

Possible cause

Remedy

Valves do not switch

Operating voltage not present or

insufficient

Check the electrical connection

Provide operating voltage acc. to nameplate

Manual override knob not in neutral
position

Turn knob to zero position

Pressure supply insufficient or not present

Execute pressure supply with as large a

volume as possible (also for upstream
devices such as pressure controllers,

maintenance units, shut-off valves, etc)

Minimum operating pressure > 2 bar

Valves switch with
delay or blow out at
the vent connections

Pressure supply insufficient or not present

Execute pressure supply with as large a

volume as possible (also for upstream
devices such as pressure controllers,

maintenance units, shut-off valves, etc)

Minimum operating pressure > 2 bar

Venting of exhaust air channels insufficient

because silencers are too small or
contaminated (backpressure)

Use matching, large-sized silencers or

expansion vessels.

Clean the contaminated silencers.

Contamination or foreign bodies in pilot or
main valve

Pressurized the exhaust air channels in
pulses to blow out contamination

Install a new pilot or main valve if pulses of

compressed air bring no result.

Leaky valve blocks

Flat seals missing or wrongly positioned
between valve and baseplate

Insert missing seals or replace damaged

seals.