Burkert Type 1062 User Manual

Page 18

Advertising
background image

18

Assembly

Type 1062

D

J

E

H

→

Check that the seal "H" is fitted and
that it is correctly positioned inside
the actuator.

→

Insert the duplication system "D" into
the actuator.

→

Screw the duplication rod "E" onto
the actuator rod "J".

→

Tighten the adaptor until free contact
is obtained with the top of the
actuator, using a flat No 27 spanner.

E

→

Check that the seals have been fitted
and that they are undamaged. Replace
them if necessary.

→

Put thread lock into the internal thread
in the duplication rod "E".

F

G

→

Unscrew the small transparent cap "F"
on the actuator, preferably by hand or
using a suitable tool in order not to
damage it (except for actuators size
40mm).

→

Pump air into the actuator on a valve
which is normally closed (function "A")
or has a double effect (function "I") so
that the actuator rod moves to the top
position.

→

Unscrew the visual position feedback
"G" using a hexagonal male spanner.

english

Advertising
This manual is related to the following products: