Assembly

Type 1062

O

H

J

L

N

K

P

M

→

Check that the seal "H" is fitted
and that it is correctly posi-
tioned inside the actuator.

→

Screw the adapter nut "J" in the
top part of the actuator.

→

Screw the connecting pin "K"
with locknut "L" in the adapter
nut "J".

→

Adjust the stroke of the actuator
(by more or less screwing the
connecting pin "K") depending
on the operating mode of the
valve:

- if the valve operates as nor-

mally closed (NC), adjust
the stroke by starting valve
closed.

- if the valve operates as nor-

mally open (NO), adjust the
stroke by starting valve open.

→

Block the locknut "L".

→

Insert the seal "M" in the con-
necting pin "K".

→

Screw the stem "N" on the
stem "O" of the actuator.

P

→

Insert the protection hood "P".

D

→

Insert the duplication system
"D" into the stroke limiter.

english