Technical Data

6. TECHNICAL DATA

DANGER!

Danger of explosion!
If the safety data and values specified on the rating plate are
not observed or maintained, hazardous situations may be the
consequence!
• Observe the degree of protection and temperature class when

using the device.

It is a safety risk to exceed the voltage indicated on the rating
plate, as this may cause the device to overheat!
• Do not connect the device to a higher voltage than indicated on

the rating plate.

Fuse

F. , . . A

II 2G Exmb II T4
II 2G Ex mbD21 IP64
Tmed130°C 24V AC/DC
12W AC19-U5-K-PF09

PTB 07 ATEX 2063 X
IEC Ex PTB08.0016X

Example

Fig. 3 : Example of rating plate for coil AC19 as part of a closed system.

Wording on the rating plate:

II 2G Exmb II T4
II 2D Ex mbD21 IP64
Tmed130°C 24V AC/DC
12W AC19-U5-K-PF09

PTB 07 ATEX 2063 X
IEC Ex PTB08.0016X

PTB approval no.

IEC explosion protection
approval no.

Device group

Device category

Ignition protection type

Gas group
Temperature class

Protection class:

- Power consumption
- Coil type
- Connection size for-

fluid component
- Coil size

- Code (specific to

company)

- Maximum surface

temperatur of the coil
(for dust)

- Voltage
- Current type

Serial no. of the coil

Ident. no.

Date of manufacture - factory/month/year

Monitoring centre

II 2G Exmb II T4

II 2D Ex mbD21 IP64

english

07 ATEX 2063 X