General safety instructions – Burkert Type 6027 User Manual

Page 6

Advertising
background image

6

General Safety Instructions

3. GENERAL SAFETY INSTRUCTIONS

These safety instructions do not make allowance for any
• contingencies and events which may arise during the installation,

operation and maintenance of the devices.

• local safety regulations, whereby the operator is responsible for their

compliance, by the installation personnel too.

DANGER!

Danger of explosion!
Following installation, solenoid coil and valve body form a closed
system. If used in the EX area, there is a danger of explosion if the
system is opened during operation!
• The system must not be disassembled during operation.
Danger of explosion caused by electrostatic charge!
If there is a sudden discharge from electrostatically charged devices
or persons, there is a danger of explosion in the EX area.
• Take appropriate measures to prevent electrostatic charges in the

EX area.

• Clean the device surface of the solenoid valve by gently wiping

it with a damp cloth

DANGER!

Risk of electric shock!
There is a serious risk of injury when reaching into the equipment.
• Only trained electrical engineers may work on the electrical

system.

• Before starting work, always switch off the power supply and

safeguard to prevent re-activation!

• Observe applicable accident prevention and safety regulations

for electrical equipment!

Danger of burns/danger of fire during long-term operation!
The solenoid coil may become very hot during long-term operation.
• Take hold of a device which has been running for a prolonged

period with protective gloves only.

Danger – high pressure!
There is a serious risk of injury when reaching into the system.
• Only skilled and instructed personnel may work on the system

with suitable tools.

• Before disconnecting lines and valves, switch off the pressure

and bleed the lines.

• During installation note the direction of flow.
• Observe applicable accident prevention and safety regulations

for pressurised devices!

• After an interruption in the power supply or fluid supply, ensure

that the process is restarted in a defined or controlled manner!

english

07 ATEX 2063 X

Advertising