Installation

DANGER!

Risk of short-circuit!
Damaged connection cables may cause a short-circuit.
• The connection cables for the coil must be laid permanently and

protected against damage.

Danger of burns/danger of fire during long-term operation!
The solenoid coil may become very hot during long-term operation.
• Take hold of a device which has been running for a prolonged

period with protective gloves only.

WARNING!

Danger – high pressure!
There is a serious risk of injury when reaching into the system.
• Only skilled and instructed personnel may work on the system

with suitable tools.

• Before disconnecting lines and valves, switch off the pressure

and bleed the lines.

• Observe applicable accident prevention and safety regulations

for pressurised devices!

• After an interruption in the power supply or fluid supply, ensure

that the process is restarted in a defined or controlled manner!

7.2. Installation

The solenoid valve with integrated coil AC19 can be ins-
talled in any location. Preferably with top-mounted drive.

Prior to installation:

→

Clean any dirt off the pipelines and flange connections.

Installation:

WARNING!

Risk of injury from leaking connections
Danger of explosion!
There is a danger of explosion in fuel pumps if oxygen or air pene-
trates the medium through leaking connections.
Risk of injury from escaping medium!
Medium which escapes through leaking connections may result in
injuries (e.g. burns or chemical burns).
• Carefully seal the connection lines.

→

Seal pipeline connections with PTFE tape. The tape must not be
dropped into the pipelines.

→

Screw in pipelines.

Important for function of the device!
Note the direction of flow.

→

Check valve for leakage.