13

Installation

DANGER!

Risk of short-circuit!
Damaged connection cables may cause a short-circuit.
• The connection cables for the coil must be laid permanently and

protected against damage.

Danger of burns/danger of fire during long-term operation!
The solenoid coil may become very hot during long-term operation.
• Take hold of a device which has been running for a prolonged

period with protective gloves only.

WARNING!

Danger – high pressure!
There is a serious risk of injury when reaching into the system.
• Only skilled and instructed personnel may work on the system

with suitable tools.

• Before disconnecting lines and valves, switch off the pressure

and bleed the lines.

• Observe applicable accident prevention and safety regulations

for pressurised devices!

• After an interruption in the power supply or fluid supply, ensure

that the process is restarted in a defined or controlled manner!

7.2. Installation

The solenoid valve with integrated coil AC19 can be ins-
talled in any location. Preferably with top-mounted drive.

Prior to installation:

Clean any dirt off the pipelines and flange connections.

Installation:

WARNING!

Risk of injury from leaking connections
Danger of explosion!
There is a danger of explosion in fuel pumps if oxygen or air pene-
trates the medium through leaking connections.
Risk of injury from escaping medium!
Medium which escapes through leaking connections may result in
injuries (e.g. burns or chemical burns).
• Carefully seal the connection lines.

Seal pipeline connections with PTFE tape. The tape must not be
dropped into the pipelines.

Screw in pipelines.

Important for function of the device!
Note the direction of flow.

Check valve for leakage.

english

07 ATEX 2063 X