Changing the electrical function module, Changing the electrical function module 8.4 – Burkert Type 8644 User Manual

Page 59

Advertising
background image

59

Installation

NoTE!

Alternative for large valve blocks:

Remove the predecessor module,

→

Snap the valve block onto the standard rail,

→

Slide the block to its final position,

→

Snap on the predecessor module again.

→

changing the electrical function module

8.4.

DANgEr!

danger – high pressure!

Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.

•

risk of short-circuit!

Do not insert any foreign objects into the base module (24 V supply bus)!

•

The function module is a component of the electronic base module. It can be replaced in consideration of the points
listed below:

Depressurize AirLINE system.

→

Using a screwdriver, loosen the fastening screws of the valves.

→

Remove valve from the valve plug.

→

Flange seal and O-ring (3/2-Way valve) must not be soiled.

→

Detach function module above rear catch mechanism and remove vertically without tilting it from the distributor

→

module (backplane bus).

Place new function module vertically on the distributor module (backplane bus) and press down until it clicks

→

into position.

Connect valve, with the cleanly inserted flange seals / O-rings, to the valve slot and tighten the screws

→

according to the following assembly diagram (see

Figure 32:Tightening the screws).

20 Ncm

20 Ncm 30 Ncm

30 Ncm

Figure 32:

Tightening the screws