Burkert Type 8030 User Manual

Page 4

Advertising
background image

12

v

ersion

of

elec-

tronic

module

se

30

s

upply

voltage

o

utput

o

rder

code

Hall

12-36 V DC

2 transistors,
NPN and
PNP

423913

Hall Low
Power

energized via the

Bürkert transmitter

the flow sensor is

connected to

1 NPN
transistor

423914

Ordering codes of fitting S030 can be found within the
related data sheet: refer to the data sheet to select the
fitting appropriate to the process.

English

13

6. TechnicAl DATA
conditions of use

Ambient temperature
(operating)

-15 °C to +60 °C

Air humidity

< 80%, non condensated

Protection rating

IP65, female connector wired,
plugged and tightened

conformity to standards and
directives

The device conforms to the EC directives through the
following standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• Pressure: The S030 fitting complies with article 3 of §3

from 97/23/CE directive.

Acc. to pressure directive 97/23/CE, the fitting can only
be used in the following cases (depending on the max.
pressure, the DN of the pipe and the fluid):

type of fluid

conditions

Fluid group 1 § 1.3.a only DN ≤ 25
Fluid group 2 § 1.3.a DN ≤ 32

or DN > 32 and PNxDN ≤ 1000

Fluid group 1 § 1.3.b PNxDN ≤ 2000

English

13

14

type of fluid

conditions

Fluid group 2 § 1.3.b DN ≤ 200

General data

Pipe diameter

DN6 to DN65
The appropriate diameter is deter-
mined using the flow rate / DN / fluid
velocity graphs.

Pressure class

Depends on the material of the fitting
used and on the fluid temperature:
refer to the operating instructions of
the fitting used.

Fluid temperature

• with fitting S030 in

metal or PVDF

• with fitting S030

in PP

• with fitting S030 in

PVC

The fluid temperature may be restricted
by the fluid pressure: refer to the ope-
rating instructions of the fitting used.
• -15 to +100 °C

• 0 to +80 °C

• 0 to +50 °C

Type and data of the
fluid

refer to the operating instructions of
the fitting used.

English

15

Flow rate measuring

range

0,3 to 10 m/s

Accuracy, with standard

K factor

≤ ±

(0.5 % of the full scale + 2.5 % of

the measured value)*

Linearity

≤ ± 0,5 % of the full scale (10 m/s)*

Repeatability

± 0,4 % of the measured value*

* Determined in the following reference conditions: medium =
water, water and ambient temperatures 20 °C, min. upstream and
downstream distances respected, appropriate pipe dimensions

English

15

Advertising