Burkert Type 8012 User Manual

Page 22

Advertising
background image

22

Technicaldata

Type 8012

Type of fluid
(optical sensor)

transparent to infrared rays

Max. temperature
of the fluid

Fitting in stainless steel, brass, PVDF:
a) 100 °C if the ambient temperature ≤ +45 °C
b) 90 °C if the ambient temperature is
between 45 °C and 60 °C
Fitting in PP: 80 °C
Fitting in PVC: 60 °C

Min. fluid
temperature

Fitting in stainless steel, brass: -15 °C
Fitting in PP or PVC: +5 °C
Fitting in PVDF: -15 °C

Fluid pressure

depends on the fitting material; see the
pressure / temperature diagramme in chap.
7.1

Fluid viscosity

300 cSt max.

Rate of solid
particles

1% max.

Measurement
range

0.3 m/s to 10 m/s (depending on the fitting)

Measurement
accuracy

≤ ± (0.5% of the full scale (10 m/s) + 2.5%
of the measured value), with standard K
factor

Linearity

≤ ±0.5 % of the full scale (10 m/s)

Repeatability

0.4% of the measured value

Measuring
element

magnetic or optical sensor

Velocity of fluid [m/s]

Typical Bürkert
curve
With standard K
factor (no cali-
bration on site)

Max. error [%]

1

9

2 3 4 5 6 7 8

10

2

4

6

8

10

-2

-4

-6

-8

-10

Fig. 2 : Measurement accuracy. These values were determined in

the following reference conditions:
medium = water, water and ambient temperatures 20 °C,
min. upstream and downstream distances respected,
appropriate pipe dimensions

English

Advertising
This manual is related to the following products: