Burkert Type 8012 User Manual

Page 27

Advertising
background image

27

Installationandwiring

Type 8012

→

Install the device on the pipe in such a way that the upstream
and downstream distances are respected according to the
design of the pipes, as per Fig. 4 and the EN ISO 5167-1
standard.

With regulating valve

Pipe with 2 elbows at 90°

in 3 dimensions

Pipe with 2 elbows

at 90°

Pipe with 1 elbow at 90°

or 1 T-piece

With pipe expansion

With pipe reduction

50 x DN

5 x DN

40 x DN

5 x DN

25 x DN

5 x DN

20 x DN

5 x DN

18 x DN

5 x DN

15 x DN

5 x DN

Fig. 4 : Upstream and downstream distances depending on the

design of the pipes.

→

If necessary, use a flow conditioner to improve measurement
precision.

→

Install the device in such a way that the paddle-wheel axis is
horizontal (Fig. 5).

→

Prevent the formation of air bubbles in the pipe in the section
around the device (Fig. 6).

→

Ensure that the pipe is always filled in the section around the
device (Fig. 7).

Correct

Incorrect

Fig. 5 : The paddle-wheel axis must be horizontal

English