SE56

25

where fs

max

is the maximum full scale value corresponding to the sensor, equal to a 10m/s liquid

speed. The measure units are shown as appear on the display. The British and American units are
diversified by using capital and small characters.

When a mass measure unit is set, the specific gravity function is automatically enabled by the
system. Please, note that the mass measure is heavily affected by the temperature. With certain
liquids this may cause significant measurement errors. The following time measure units can be
selected: s = second, m = minute, h = hour, d = day.
(POS. 2.3) Measure unit and decimal places number

[Tot.MU=dm³ X.XXX]

Setting the measure unit and decimals places number displayed for the volumes. To set the
measure unit, position the cursor on the measure unit field. To set the unit type, position the cursor
on the blank space between the measure unit and the numeric value; the decimal places number
can be selected by placing the cursor on numeric field and choosing one of the possible
combinations: 1000-01.00-001.0-00001.
(POS. 2.4-5) Pulse value channel 1-2 and total measure unit

[Pls1-2=dm³ X.XXXXX]

Setting of a flow volume by which a corresponding pulse will be emitted on channel 1-2, units must
be identical to ‘Full scale’ and ‘Totalizer’ functions. To set the parameter, complete the three fields,
from left to right: 1) measure unit, 2) unit type and 3) numeric value. The selection is performed by
positioning the cursor in the field to be modified. To change the unit type (metric, British or
American, mass or volume) position the cursor on the blank space between the measure unit and
the numeric value. When the nominal diameter is set to zero it is possible to modify only the
numeric field since the measure unit stays at meters (m) or feet (ft). Only those units described
above are available to be selected. This function is active only if the pulse emission on channel is
enabled.
(POS. 2.6-7) Pulse duration channel 1-2

[Tpls1-2=ms XXXX.XX]

Setting of the pulse duration generated on channel 1-2. This value is expressed in milliseconds and
has to be between 0.4 and 9999.99. When the high frequency output is present, then the minimum
value can be set to a minimum of 0.04 milliseconds. ATTENTION: since the transmitter cannot
detect which device type is connected to the transmitter, the user must verify that the set pulse
duration is compatible with the external device processing such pulses. If, for example, an electro-
mechanical pulse counter is connected, one of two problems may occur; firstly, if the pulse is too
long the coils may burn out, secondly, if the pulse is too short, the counter may not be able to
function, with the possibility of causing damage to the output.

in

3

Cubic inch

Gal

American gallon

GAL

British gallon

ft

3

Cubic foot

Bbl

Standard barrel

BBL

Oil barrel

yd

3

Cubic yard

kgl

KAmerican gallon

KGL

KBritish gallon

cm

3

Cubic centimeter

ml

Milliliter

L

Liter

dm

3

Cubic decimeter

dal

Decalitre

hl

Hectolitre

m

3

Cubic meter

Oz

Ounce

Lb

Pound

Ton

Short tons

g

Gram

kg Kilogram
t

Ton