Technical data, Operating conditions – Burkert Type 2051 User Manual
Page 12

12
Technical Data
6.
Technical daTa
Operating conditions
6.1.
Temperature
seal material
ambient temperature
NBR Spezial
-40 ... +80 °C
FKM
-15 ... +150 °C
conformity with the following
6.2.
standards
CE - mark conforms to EN 1127-1 EN 13463-1
general technical data
6.3.
mechanical data
6.3.1.
Weight:
1.0 to 17.0 kg
depending on actuator design
Housing material:
coated, extruded aluminum alloy
Sealing material:
NBR-Special,
FKM on request
pneumatic data
6.3.2.
Control medium:
Compressed air (max. Particle size 30 µm)
dry or oiled
Pressure range:
3 to 8 bar single-acting actuator
2.5 to 8 bar double-acting actuator
Air rate:
0.09 to 4.0 l,
depending on actuator size
Connections:
G 1/8" for actuator size 15 - 100
G 1/4" from actuator size 150
dimensions
6.3.3.
Dimensions:
See data sheet
english
Type 2051