15

Maintenance, Troubleshooting

10.

mainTenance,
TrOuBleshOOTing

safety instructions

10.1.

Danger!

danger - high pressure in the equipment!

Before loosening the lines and valves, turn off the pressure and

•

vent the lines.

Warning!

risk of injury from improper maintenance!

Maintenance may be carried out by authorised technicians only

•

and with the appropriate tools!

risk of injury from unintentional activation of the system and
uncontrolled restart!

Secure system from unintentional activation.

•

Following maintenance, ensure a controlled restart.

•

maintenance work

10.2.

It is recommended to perform maintenance after every 500 000 to
1 000 000 circuit connections to guarantee a long service life of
swivel actuators. If necessary, the respective sealing elements must
be replaced (see the following chapter

10.3.Replacing of the sealing

elements).

For long-term operation or rough ambient conditions, we recommend
relubrication of the moving parts (e.g. pistons, gear racks) in the actuator
with silicone-free grease (e.g. Barrierta LF 55/3).

A prerequisite for a long service life is the operation of the swivel
actuator with filtered compressed air.