FLUID COMPONENTS INTL

APPENDIX D - MT91 DELTA R PARAMETERS

Model MT91 Multipoint Flowmeter

D - 2

Doc. No. 003185 Rev. B

5.2.1 Verify Cal Inputs

URRG1

Unipolar Reference R Gain

Channel 1

URRG2

Channel 2

URRO1

Unipolar Reference R Offset

Channel 1

URRO2

Channel 2

UDRG1

Unipolar Delta R Gain

Channel 1

UDRG2

Channel 2

UDRO1

Unipolar Delta R Offset

Channel 1

UDRO2

Channel 2

BRRG1

Bipolar Reference R Gain

Channel 1

BRRG2

Channel 2

BRRO1

Bipolar Reference R Offset

Channel 1

BRRO2

Channel 2

BDRG1

Bipolar Delta R Gain

Channel 1

BDRG2

Channel 2

BDRO1

Bipolar Delta R Offset

Channel 1

BDRO2

Channel 2

RxAdj1

Reference Adjust

Output Board 1

(sensing points 1 through 8)

RxAdj2

Reference Adjust

Output Board 2

(sensing points 9 through 16)

HtAdj1

Heater Adjust

Sensing Point 1

HtAdj2

Sensing Point 2

HtAdj3

Sensing Point 3

HtAdj4

Sensing Point 4

HtAdj5

Sensing Point 5

HtAdj6

Sensing Point 6

HtAdj7

Sensing Point 7

HtAdj8

Sensing Point 8

HtAdj9

Sensing Point 9

HtAdj10

Sensing Point 10

HtAdj11

Sensing Point 11

HtAdj12

Sensing Point 12

HtAdj13

Sensing Point 13

HtAdj14

Sensing Point 14

HtAdj15

Sensing Point 15

HtAdj16

Sensing Point 16

5.2.2 Verify Cal Outputs

Zero[1]

A to D Values

Zero[2]

A to D Values

Span[1]

A to D Values

Span[2]

A to D Values

Slope[1]

A to D Values

Slope[2]

A to D Values

Off[1]

A to D Values

Off[2]

A to D Values

CorrF[1]

Correction Factor 1

CorrF[2]

Correction Factor 2

CorrF[3]

Correction Factor 3

CorrF[4]

Correction Factor 4

5.2.3.1 Verify Cal Flow Limits

FlowMin

Customer specified and factory calibrated value
for minimum flow.

FlowMax

Customer specified and factory calibrated value

for maximum flow.

TempMin

Customer specified and factory calibrated value
for minimum temperature.

TempMax

Customer specified and factory calibrated value

RRmin

Reference R minimum Calibration Value

RRmax

Reference R maximum Calibration Value

dRMin 1

Delta R minimum Calibration Value

Sensing Point 1

dRMin 2

Sensing Point 2

dRMin 3

Sensing Point 3

dRMin 4

Sensing Point 4

dRMin 5

Sensing Point 5

dRMin 6

Sensing Point 6

dRMin 7

Sensing Point 7

dRMin 8

Sensing Point 8

dRMin 9

Sensing Point 9

dRMin 10

Sensing Point 10

dRMin 11

Sensing Point 11

dRMin 12

Sensing Point 12

dRMin 13

Sensing Point 13

dRMin 14

Sensing Point 14

dRMin 15

Sensing Point 15

dRMin 16

Sensing Point 16

drMax 1

Delta R maximum Calibration Value

Sensing Point 1

drMax 2

Sensing Point 2

drMax 3

Sensing Point 3

drMax 4

Sensing Point 4

drMax 5

Sensing Point 5

drMax 6

Sensing Point 6

drMax 7

Sensing Point 7

drMax 8

Sensing Point 8

drMax 9

Sensing Point 9

drMax 10

Sensing Point 10

drMax 11

Sensing Point 11

drMax 12

Sensing Point 12

drMax 13

Sensing Point 13

drMax 14

Sensing Point 14

drMax 15

Sensing Point 15

drMax 16

Sensing Point 16