Fluid Components International ST100 Series Modbus User Manual
Page 10

ST100 Series Modbus Operation
6
Fluid Components International LLC
Figure E
3. How to check/set the “Totalizer Max” value?
• Repeat the step (1A) with the different register numbers. Set the registers #4115 and #4116.
• Repeat steps (1B) and (1C).
• See the below Figure E for the “Ceiling value”.
4. How to reset the totalizer value?
• Repeat step (1A) with the register number 4117.
• Repeat step (1B).
• Double click on the register number as shown in the Figure F. New window will pop-up. Write the defined value (ABCD in
Hexadecimal form),
Figure F
5. How to Start and Stop the totalizer value?
• Repeat step (1A) with the register number 4118.
• Repeat step (1B).
• Double click on the register number as shown in the Figure G. New window will pop-up. Write the defined value (“1” to start
and “0” to stop.).
Figure G
Double Click
Double Click