Caution, Signet 2552 frequency/s, L out – GF Signet 3-0250 USB to Digital (S3L) Configuration-Diagnostic Tool User Manual

Page 2

Advertising
background image

2

Signet 0250 Setup Tool

Connect the Magmeter to the computer:
• Connect the Magmeter to the 3-0250 as illustrated.
• For 3-2551-11 models: The frequency/digital jumper MUST be in the Digital position.
• Connect the isolated 24 VDC power source to 4-20 mA model Magmeters.
• Connect the Signal Converter to any open USB port on the computer.

CAUTION!

TURN 24 VDC POWER OFF WHEN WIRING THE MAGMETER.

System connections
Signet 2552 Metal Magmeter

System connections
Signet 2551 Blind Magmeter

2551 and 2552 Magmeters

The setup capability of the 0250 is more complex with the magmeters than with other sensors. Read these instructions carefully before
attempting to modify a Magmeter.

CAUTION!

Do not connect power

directly to this device.

White

Blue

Brown

Black

Isolated
24 VDC

+

-

White

Blue

Wire Nut

To -VDC

*Wire 1

*Wire 2

*Wire 3

* Additional wire required

Signet 2552
4-20 mA Out

Data

+5 VDC

Ground

White

Brown

Black

Blue

Signet 2552
Frequency/S

3

L Out

1

2

3

4

2551 Blind Magmeter
Frequency/S

3

L Out

JP2

FREQUENCY OUT
DIGITAL (S

L) OUT

3

Freq/Digital jumper
must be in Digital position

GND
Data
5V out+

USB

1

2

3

4

GND

Data

5V out+

Isolated
24 VDC

+

-

2551 Blind Magmeter
4-20 mA Out

USB

CAUTION!

Do not connect power

directly to this device.

Advertising