SECTION - 3

DESCRIPTION

INPUT AND OUTPUT TERMINATION :
The unit works from 115VAC, 47Hz to 63Hz single phase supply
with internal tap selection facility. The input is provided through a
mains cable with a plug. The use of a three core cable enables the
cabinet of the unit to be properly grounded.
The unit as shipped from factory is wired for 115V AC single phase
supply
Output is provided on two seperate sockets through a output voltage
range selector switch. In one position, it provides 0 -130 VAC at 4A
max whereas in other position,it provides 0-260VAC at 2Amp.max.

METERING :
One 3-digit DPM is provided to measure
1)

Output voltage

2)

Leakage current

3)

Load current
Meter function is switch selectable

ON-OFF SWITCH AND FUSE :
The power ON-OFF switch is located on the front panel. The fuses
(Input & Output) are also located on the front panel. The fuse ratings
are clearly marked.

PANEL CONTROLS :
A voltage adjust knob allows adjustment of output AC voltage and
the output voltage selector switch selects the output AC voltage
range so as to provide 0 -130VAC isolated output only on American
socket while 0 - 260VAC isolated output only on European socket.
Three meter function push switches are provided to select the
Leakage Current or Output Voltage or Output Current (mA,V & A
respectively.) to be displayed on the meter.

CIRCUIT DESCRIPTION :
The circuit uses a step down tranformer to provide step down supply
to a single phase variable autotrans former to obtain an output
voltage variable from 0 to 130VAC. This is followed by a triple
shielded isolation transformer which provides an output voltage from
0-130VAC or 0-260VAC electrostatic and galvanic isolation.
Multiple shielding technique reduces primary to secondary static
coupling to below 0.0005pF. The DC isolation is over 1000 M Ohms.

3

SECTION - 7

PART LIST

PCB Components

GLOBAL 1505 / 06 SW - 0396

=======================================================================

Reference Designator

Part Description

=======================================================================

RESISTORS
R1

1.5K, ¼W ±5% MFR

R2

120E, ¼W ±5% MFR

R3

10K, ¼W ±5% MFR

R4

62K, ¼W ±5% MFR

R5

10 ohm, ¼W ±5% MFR

R6

220 ohm, ¼W ±5% MFR

R7

Not Used

R8

10K, ¼W ±5% MFR

R9

100K, ¼W ±5% MFR

R10

10M, ¼W ±5% MFR

R11

4.7K, ¼W ±5% MFR

R12

10K, ¼W ±5% MFR

R13

1.2M, ¼W ±5% MFR

R15

470K, ¼W ±5% MFR

CAPACITORS
C1

1µf, 50V ±20%, ELEC

C2

1µf, 50V ±20%, ELEC

C3

220µf, 16V ±20%, ELEC

C4

220µf, 50V ±20%, ELEC

C5

0.1µf, 100V ±10%, MP

C6

0.22µf, 100V ±10%, MP

PRESETS
PR1

100E Horizontal

PR2

100E Horizontal

PR3

100E Horizontal

PR4

10K Horizontal

DIODES
CR1

1N4007

CR2

1N4148

CR1

1N4148

8