Specifications measurement ranges – GxT Ferret 54 ENGINE DIAGNOSTIC CENTER User Manual

Page 98

Advertising
background image

SPECIFICATIONS

Measurement Ranges

IGNITION

Volts, Battery .......................................... to 20.00 Volts
Volts, Aux (10 Megohm) ...........................

±

20.00 VDC

................. to 50.0 VAC Pk-Pk

Amps - Inductive .........................................

±

600 Amps

Tachometer ....................................... 100 to 5,000 RPM
Dwell, Ignition ............................. Degrees, %, or mSec.
Driver/Points Resistance ............................. to 3.0 Volts
Dwell Variation ............................................ in Degrees
Timing Variation .......................................... in Degrees
Timing Advance ......................................... 90 Degrees
Ignition Coil Amps ....................................... 19.9 Amps
Coil Amps Build Time .................................... 9.9 mSec
Spark Burn Time ........................................... 9.9 mSec
Ignition Energy ............................. 99 milliVolt-Seconds
Secondary KV ............................................ 32 Kilovolts

Pulse Rate (Frequency) ............................... 999 Hertz
Cylinder Power Balance ........................... % RPM Drop
Cylinder Power Contribution ...................... Speed Index
Amps Ripple .................................... Message Indicator
Cranking Compression .......................... % Amps Peak
Injector Amps Drive Time ............................ 99.9 mSec
Injector Peak Amps ..................................... 19.9 Amps
Throttle Position Sensor ......................... Glitch Catcher
O2 Sensor ..................................... Volts and Crossings
Oil Temperature .......................................... 0

°

to 300

°

F

With optional sensors:
Vacuum .......................................................... to 30" Hg
Pressure ......................................................... to 15 PSI

Diesel RPM ...................................... 100 to 5,000 RPM

EMISSIONS

TEST

RANGE

ACCURACY

HC

-

Hydrocarbons
hexane

0 - 2000 ppm

0 - 120

6 ppm

> 120

5% of reading

CO

-

Carbon Monoxide

0 - 10.00 %

0 - 1.2 % 0.06 %

> 1.2% 5% of reading

CO2

-

Carbon Dioxide

0 - 20.0 %

0 - 10 %

0.5 %

> 10% 5% of reading

O2

-

Oxygen

0 - 21.0 %

0 - 2 %

0.1 %

> 2%

5% of reading

NOx

-

Oxides of Nitrogen

0 - 4000 ppm

0 - 1000 ppm range ............................... 32 ppm
1001 - 2000 ppm range ........................ 60 ppm
2001 - 4000 ppm range ...................... 120 ppm

Temperature

5

°

- 150

°

C

.......................... 40

°

- 300

°

F

Vehicle O2 Voltage

0 - 1.2v

DIMENSIONS

Physical

61 x 51 x 145 cm .......... 24 x 20 x 57 inches

Leads

4.3 m

.................................... 14 feet

Sampling Hose

8.5 m

.................................... 28 feet

Operating Temperature

2

°

to 49

°

C 35

°

to 120

°

F

Storage Temperature

-29

°

to 54

°

C .................... -20

°

to 130

°

F

Shipping Weight

80 kg

.................................... 175 lb.

With Gas Analyzer

90 kg

......................................... 200

Power Requirement

12V Vehicle Battery

9-5

Advertising