Recommended Maintenance


The recommended service and maintenance on the AQUA-LAB System are as follows.


Monthly

Check air regulator

Check water filter and replace as needed (if installed)


Semi-Annually

Check and replace injector metering tips

Check and clean wye strainer

Inspect and replace chemical lines as needed

Ensure lines are tightly secured to injector hose barbs, clip 1” off old hose as needed that was stretched
by hose barb

Annually

Clean water regulator

Inspect motor starter for corrosion, if identified order replacement/spare parts

1-3 Years

Inspect and replace injectors

Replace water valves

Replace main pressure regulator