Pressure regulator issues, Flow / arch issues, Valve issues – Hydra-Flex Aqua-Lab EVO User Manual User Manual
Page 14

© Hydra-Flex Inc 2014
Page | 12
Pressure Regulator Issues
Problem
Potential Causes
Solutions
System won’t
regulate up to 200
psi
Pump not primed
Follow priming instructions
Debris in regulator
Remove regulator and clean out debris
Motor rotation incorrect
Verify rotation
Opening too many valves at once
System is limited by size of pump and size of
injectors, increase flow by adding secondary pumps
or reduce size / number of injectors open
Defective check valve (if applicable)
Replace check valve
Defective Regulator
Replace regulator
Defective Pump
Replace Pump
Flow / Arch Issues
Problem
Potential Causes
Solutions
Flow at arch is too
low
Incorrect injector flow rate selection
Replace with larger injector
System pressure too low
Ensure system pressure is set at 200psi
Foam Generator Plugged
Ensure cleaned and clear
Downstream plumbing restrictive
Increase size of plumbing / tubing, ensure check
valves are cleaned or new, reduce elbows in line or
other turns that would restrict
Valve Issues
Problem
Potential Causes
Solutions
Valve won’t open
Air pressure too low
Ensure primary air regulator reading at least 60 psi,
turn up to 80-90psi if possible and check again
Internal valve o-ring jammed / twisted
Remove valve from manifold, Carefully remove top
of valve
(caution – under high spring pressure)
push white piston up with small allen wrench from
opposite end and check o-ring condition. Replace
and lubricate if needed.
Valve leaks air or
water out top
Internal o-ring seal damaged / worn
Remove valve from manifold, Carefully remove top
of valve
(caution – under high spring pressure)
push white piston up with small screwdriver from
opposite end and check o-ring condition. Replace
with 018 Viton O-ring and lubricate with Dow 111
valve lube.
Valve remains open
after signal is off
Manifold pressure is above 230 psi
Reduce pressure to manifold to 200 psi operating
pressure