Specifications

1. Operating water pressure: 180- 200 psi - Do Not Operate Pump Above 225psi
2. Pneumatics operating pressure: 80-100 psi – Do Not Operate Valves Above 100psi
3. Maximum water source temperature 140° F
4. Operating ambient temperature: 40-120° F
5. Electrical supply

a. 208/230 or 480 volts (3-phase)
b. 2 hp pump 7.4 amps @ 230 volts or 3.7 amps @ 480 volts
c. Overload Setting 8.0 @ 230 volts or 4.0 @ 480 volts

6. Operate solenoid valves with 24VAC, 24VDC, 120VAC

a. 3.5 watts per port

7. Water supply

a. 3/4” ID line pump feed
b. Inlet pressure: 2-80 psi

i. If pumps are fed from tank, water level must be 54” above pumps.

8. Air supply

a. 3/8” feed per system
b. 20 CFM @ 80-100 psi supply

9. Solution lines

a. 3/8” ID poly lines for 3.25GPM and below
b. ½” ID poly line for 3.25 to 5.5 GPM
c. .63 ID poly line for 5.5 – 8 GPM

10. Space requirements:

a. 38”W x 44”H with pump assembly